Preparing Network
When planning your Genian NAC Deployment onto your network there are several considerations.
- Where should the equipment be placed?
- How will it connect to my switches?
- How many pieces of equipment do I need?
- What ports do I need to open for Genians to communicate?
Wired Connectivity
The Policy Server should be directly connected to your Core Switch port as an access port. The Network Sensor should be connected to an Edge Switch port that can be an access port, or trunk port.
Switches
Network Sensors must be able to see broadcast packets, so they must be connected to all managed subnets.
VLANs
To monitor multiple VLANs (up to 128,recommended 64) through a single port, make sure the switch port is configured with 802.1Q trunking and that all VLANs you wish to monitor are allowed on that port.
Switches differ in how to configure this setup.
Below are examples of how to configure 802.1Q Trunk ports for VLANs on common switches. In these examples, we will show how to add VLANs 100 and 200 to port 48, configured with .1q trunk encapsulation.
Cisco Switch
Cisco(config)#interface gi1/0/48
Cisco(config-if)#switchport trunk encapsulation dot1q
Cisco(config-if)#switchport mode trunk
Cisco(config-if)#switchport trunk allowed vlan add 100,200
HP Switch
Procurve(config)#vlan 100
Procurve(config)#tagged 48
Procurve(config)#vlan 200
Procurve(config)#tagged 48
SNMP
Genians supports SNMP Versions 1, 2c and 3. The read-only community string is used to check whether the node supports SNMP in the process of collecting information about the Node by the network sensor. If the node responds to an SNMP request, the sensor verifies that the node is a switch by verifying that it supports the BRIDGE-MIB through an SNMP query. The read-write community string is used to make changes to the switches for port descriptions and shutting down switch ports. In addition, it can be used for various additional functions such as collecting information of wireless controller using SNMP, detecting platform information of device.
Note
Be sure to add the Network Sensor to the access-lists of all switches in the same network segment, and assign necessary permissions for users/groups to view all OIDs. For more info see: Switch Ports
WAN
If you have more then one location behind WAN Technologies then a Network Sensor would be required at each of these locations.
Wireless Connectivity
Network Sensors with Wireless NIC is used to detect wireless packets and identify SSIDs that are both Internal to your network and External (Neighboring) to your network. Placement of the Network Sensor with Wireless NIC is critical as you do not want to place this in a Data closet where you will only detect Wireless SSIDs near the data closet. You will want to place the Network Sensor with Wireless NIC centrally to where you can detect the majority of the SSIDs around it.
Firewall Requirements
The following connections must be allowed for Genian NAC to function properly.
On-Premise
SRC IP | DST IP | Service | Note |
---|---|---|---|
Policy Server IP | 54.81.159.137
d1s536j2uzv1h7.cloudfront.net (IP may vary)
Log-Server
DB-Server
Network Sensor IP, PC IP(Agent)
|
TCP/443
TCP/443
TCP/9200~9300, TCP/9300~9400
TCP/3306
UDP/3871
TCP/443
TCP/443
TCP/443
TCP/443
TCP/80, TCP/443
TCP/443
TCP/443
|
Sign-in to www.genians.com (On-Prem Only)
Download Updated Software Image (On-Prem Only)
Log-Server
Database
KeepAlive, Send Event
Alarm Service
Alarm Service
GenianData Update
GENIAN Data Update (On-Prem Only)
GenianData Update(Global)
Platform false positive report/non-detection report
Genian DPI
Join Us Login Feature
|
Network Sensor IP | Policy Server IP/FQDN
|
Various services on
unique ports
|
See UI under System > Services > Port
|
PC IP (Agent) | Policy Server IP/FQDN
|
UDP/3870
TCP/80, TCP/443
TCP/8000
|
Keep Alive
Update Information/Policy
Windows Update
|
Management PC | Policy Server IP, Network Sensor IP
Policy Server IP
|
TCP/3910
TCP/8443
|
SSH Console
WEB Console
|
Note
GENIAN Data: It required to allow the On-Premise Policy Server to get weekly/monthly updates for the Platform Detection DB, CVE and NIC Vendors.
Cloud Managed
SRC IP | DST IP | Service | Note |
---|---|---|---|
Policy Server IP | 3.34.24.101
Network Sensor IP, PC IP(Agent)
|
TCP/80, TCP/443
UDP/UNIQUE PORT
|
Platform false positive report/non-detection report
KeepAlive, Send Event
|
Network Sensor IP | Policy Server IP/FQDN
|
UDP/UNIQUE PORT
TCP/80, TCP/443
|
Keep Alive
Update Information/Policy
|
PC IP (Agent) | Policy Server IP/FQDN
|
UDP/UNIQUE PORT
TCP/80, TCP/443
TCP/8000
|
Keep Alive
Update Information/Policy
Windows Update
|
Management PC | Network Sensor IP | TCP/22 | SSH Console |
Note
UNIQUE PORT: Specific Port Info for the Cloud Managed Policy Server can be found in the Web Console by selecting System on the top panel, and then selecting Service > Port from the left menu bar.
Note
Keep Alive traffic is sent from all Sensor interfaces, including Vlan interfaces (ethX, and ethx.x)