Setting preferences for collecting remote WMI information
Windows Management Instrumentation (WMI) is a Microsoft tool for web-based enterprise management. The WMI can be used to check your device and collect information from your device.
Basic Requirements
To use WMI on a Windows endpoint, verify the following settings: Remote WMI is only available when joined to an AD domain
- Port 135/TCP must be available for WMI communication.
- The following services should be running:
- Server
- Windows Management Instrumentation (WMI)
- WMI communication must be enabled in network firewalls.
Additional Configuration/Troubleshooting Options
Verify/implement the following configuration settings to work with WMI.
- Configure the following Active Directory settings. You can configure some of these settings on endpoints using a Group Policy.
- Member of Domain Administrators or Local Administrators group
- Member of the following domain groups:
- Performance Log Users
- Distributed COM Users
- Member of a group with the following permissions:
- Act as part of Operating System
- Log on as a batch job
- Log on as a service
- Replace a process
- Run the dcomcnfg utility and configure the following endpoint permissions:
- Access Permissions: Enable all
- Launch and Activation Permissions: Enable all
- Run the wmimgmt.msc utility and configure WMI namespace security settings. Assign permissions to the following namespaces:
- rootCIMv2
- rootDefault
- rootSecurityCenter
- rootSecurityCenter2
Assign the following permissions to each of the namespaces:
- Execute Methods
- Enable Account
- Remote Enable
- Read Security