Node is not displayed in Web Console
Symptom
Case 1: None of the nodes except the Network Sensor are visible in the network subnet where the Network Sensor is installed.
Case 2: Only some nodes are visible while other active nodes are not detected.
Cause
Genian ZTNA can not scan nodes when the switch port configuration is mismatched with the Sensor interface settings.
Additionally, remote device/node discovery can be impacted when Radius Accounting, endpoint agent, or external API are not functioning properly.
Resolution
Switch
- Ensure that the port Genian ZTNA is on is properly configured to access the VLAN(s) you wish to monitor.
- Only Standard access ports (untagged) and 802.1Q Trunk (tagged) ports are supported by Genian ZTNA.
Network Sensor
- Check the interface settings by accessing the command line and using the command
show interface eth[#]
- Be aware that interface eth0 can only function when attached to an access port or in the presence of a native VLAN on a trunk port.
- All tagged VLAN traffic can only be seen by a defined sub interface on that VLAN. For configuration, see: Adding And Deleting Network Sensors
- Try to ping resources on the subnet from the network sensor to ensure a communication path exists.
If using a Virtualized Sensor
- Ensure your hypervisor is properly configured to interface with the network and your switches. Hypervisors frequently require non-standard configurations to communicate across a LAN, or to accept traffic from a trunked interface.
- Refer to: Installing Genian ZTNA , under "Prepare Network Connection."
RADIUS
- Without the presence of a Sensor, RADIUS Access-Request packets may be used to register nodes.
See RADIUS Section: